Visage 7 for Neuro ยท Jay Khurana

YNHH · Visage 7 client · Neurology field guide

Visage 7 for Neuro

Triangulate a lesion across every sequence, pull a thick-slab MIP on a code-stroke CTA, line up priors, and put your windows on number keys. Built from Visage's own manuals, two hospital guides, and a real workstation toolbar.

Checked against Visage 7 Online Help v31.00 (Sep 2026). Public sources only. Your build: Help > About.

Brain window, C:40 W:80: 0 to 80 HU spread across black to white. Everything below 0 HU shows black, everything above 80 shows white.

Start here

What you're running, and which keys it uses

Visage 7, desktop client

  • Visage 7 is the diagnostic client from Visage Imaging, a Pro Medicus company. YNHH signed its Visage 7 contract in November 2017. PR 2017
  • Every icon on the toolbar below appears in Visage's 2018 or September 2026 manual, so the legend holds across point releases.
  • Help > About shows the exact build number.
  • Visage Ease Pro is a separate phone and tablet app with its own gestures. Ease Pro

Which key map is on your workstation?

Visage changed several factory keys between its 2016-2018 manuals and the 2026 manual, and YNHH can remap keys for everyone. A ten-second test on any open image:

1Press G. If the thumbnail strip disappears, you're on the 2026 map. Press G again to bring it back.
2Nothing happened? Press . (period). If the image inverts, you're on the 2016-18 map. Press it again to undo.

Ground truth is Help > Keyboard Shortcuts. Click in the list, press Ctrl A then Ctrl C, and paste it wherever you keep notes. M18 p.54

The neuro dozen

Twelve moves that pay off on nearly every neuro study

Ordered by how often they save you time on a neuro read. Keys tagged 2026 map depend on your build; see the test above.

Alt+click

Triangulate one point everywhere

Click a lesion on DWI. Every viewer containing that point jumps to it: FLAIR, ADC, SWI, T1 post, the other planes, even unlinked series. The manual singles this out for multiseries MR.

M26 p.133Both maps
TthenShift+T

Thick slab, then MIP, MinIP, AvIP

In an MPR viewer, T switches between thin slices and a thick slab; Shift+T cycles the projection. MIP for CTA, MinIP for SWI veins and microbleeds.

1to90Shift+1

Windows on number keys

1 to 9 are your own presets, set per modality. 0 restores the default. Shift+1 and Shift+2 apply windows stored in the DICOM. Brain, subdural, stroke, bone, and CTA values are in Window presets.

wheel↑↓HomeEndPgUpPgDn

Scroll without skipping slices

Fast wheel scrolling skips slices by default (Mouse Wheel Acceleration). For a punctate DWI lesion, scroll slowly, tap the arrow keys, or pick Browse Continuously, which never skips. PgUp and PgDn step one full slab.

LShift+LJ

Link stacks in one keystroke

L links same-orientation stacks in this study. Shift+L links current and priors. J turns all linking off and on.

M26 p.269 UCSD2026 map
holdShift+scroll

Re-sync a prior that's off by a few slices

Scroll one viewer to a landmark, hold Shift, scroll the other to match, release. They stay linked at the new offset. Inside a single study, hold Shift+Ctrl instead.

double-click

Solo a viewer

Double-click any viewer to fill the screen with it. Double-click again to return to the layout.

Space

Clear the overlay text

Hides the text drawn over the image; some builds step through detail levels instead. To hide only demographics and keep your arrows, use Toggle Patient/Study Data.

SShift+SAlt+S

Screenshots for slides

Active viewer, every viewer, or all viewers merged into one image. Each lands in the Export tab: right-click it, Copy, paste into PowerPoint.

M26 p.194 UCSDBoth maps
KF11F12

Flag images with key views

K flags the current image with a yellow star; F11 and F12 step back and forward through flagged images. Every measurement makes one too. They last for the session unless saved.

M26 p.203Both maps
DAorN

Measure and label

D draws a distance; A an arrow with text (N on the 2016-18 map). Hold Ctrl while drawing to snap a line horizontal or vertical. Zoom in first: accuracy is about ±2 pixels.

Ctrl+wheel

Make the tiny text readable

Over overlay text: larger or smaller. Over a toolbar: bigger icons. Over the orientation cube: thicker scoutlines and crosshair.

Toolbar

The toolbar, decoded

A Visage 7 toolbar, numbered. Hover or tap a number to jump to its entry. Most of these tools also have a mouse or key shortcut, so you rarely need to click them.

Visage 7 toolbar: standard tools row above the layouts row

Scroll sideways to see the whole toolbar.

Window tabs: Study Browser, the patient tab, ExportTop right of your window: Study Browser finds studies, each patient gets a tab (green dot = active tab, yellow plus = new images since you opened it), and Export collects every screenshot you take. M26 p.38

Session, priors, reports

1Close Session

Unloads everything in this patient tab. If you have unsaved measurements, it asks what to do with them.

2Study Navigator

Every study on the server for this patient. Pin the priors you want, move the slider to see more, click Load. A yellow plus on this icon means new images arrived.

3Reports (RIS)

Opens the report window. The icon shows report status, and a green check means a signed report. In the Study Navigator, hovering a report icon previews the impression.

23Study Info

Read-only study details. In the 2018 manual it also held a comment box that saves to the server automatically.

Navigate and display

4Browse Slices
F6

Left-drag to scroll. Fast drags skip slices.

5Pan
F3

Right-drag pans without selecting it.

6Zoom
F4

Middle-drag zooms without selecting it; drag up to zoom in.

7Window Level
F5

Hold left and right buttons and drag: sideways for width, up and down for center. A histogram shows lower left while it is active.

8Fit Height

Fills the viewer top to bottom. In MPR, linked viewers resize too.

9Fit Width/Height
F
2026 map

Fits the whole image in the viewer.

10Zoom 100%

One image pixel per screen pixel.

11Inverse
Ior.

Black becomes white. I on the 2026 map, period on the 2016-18 map. Not available in the 3D viewer.

12Magnifying Glass ▾

Hold the click to magnify under the cursor; roll the wheel while holding to change power. The arrow offers Magnifying Glasses, one per viewer, for side-by-side detail.

Annotate, measure, capture

13Arrow/Text Annotation
AorN

Click for a text label; drag for an arrow with text. A on the 2026 map, N on the older one. Right-click it for Show on all Slices.

14Distance
D

Right-click the line for Show on all Slices, or open Tools > Line Profile for an HU plot along it.

15Perpendicular Distance ▾

Two lines held at 90 degrees, for ABC/2 and midline shift. The arrow opens more tools in this group.

16Screenshot ▾
SShift+SAlt+S

Active viewer, all viewers, or all viewers combined into one image. Each goes to the Export tab.

Linking current and prior

17Toggle Linking
J

Master switch for all viewer linking; the icon darkens when linking is on.

18Link Scrolling

Manual linking: click each viewer to join, then the check mark (Accept and Exit) in the last one's corner. Use it when automatic linking misses a series.

19Automatically Link Viewers
LShift+L
2026 map

Links same-orientation stacks using the DICOM frame of reference. Shift-click the button to switch to the across-studies version.

20Link Current Position

Alt+click the same landmark in both datasets, then click this. Visage builds a true 3D registration from that point, so oblique planes stay aligned. (I on the 2016-18 map.)

21Automatic Viewer Registration

Registers two studies on image content, rotation included, so it copes with a different head tilt. Verify it: automatic registration can misalign.

22Reset Viewer Linking ▾

Returns linking to what the protocol set up.

Layouts row (bottom)

24Modify Layout

Re-grid a monitor on the fly, for example 3×3, keeping or clearing the images.

25Layout buttons
Key ViewsCompare 1 SeriesCompare All ImagesCoronalsSagittals1 Series2 Series4 Series8 Series12 SeriesThin MPRCompare 2 SeriesCompare Thin MPRPaperwork

Layouts set up for the current protocol. Going by the names, Compare puts current beside prior, Thin MPR gives reformattable viewers where T and the crosshair work, and Paperwork holds scanned forms. Right-click a button to make it your default, then Save Layout Preferences.

26Icon labeled A…D

Not in any public Visage document I found. Hover it for the tooltip; it is probably a site-specific or integration add-on.

27Go To Next Study

Worklist and dictation tool: moves to the next study you selected. Built for radiologists reading from a worklist.

28Blue arrow with A

Also not in the public docs; it sits with the worklist tools. Hover it for the tooltip.

29Skip to Next Study

Marks the study as skipped in the worklist and moves on.

Mouse

The mouse works before you pick any tool

These defaults work in any viewer without touching the toolbar. Colors match the diagram.

Left button

Drag runs the selected tool. Default Navigation (F1) does the protocol's main job for that viewer; in the 3D viewer, that's rotate. Click makes a viewer active (brighter border). M26 p.38, 63, 131

Left + right together

Drag to window from anywhere: sideways changes width (contrast), up and down changes center (brightness). M26 p.40

Side buttons

Assign any tool in File > Preferences > Mouse Buttons. Triangulation and Next Window Level are good candidates. M26 p.272

L R 4/5
Wheel

Roll to scroll slices. Press and drag to zoom: drag up to zoom in. M26 p.39, 45

Right button

Drag to pan. Click opens the tool palette, the context menu, or both, depending on your preference setting. M26 p.39, 56

3D viewer

Ctrl + drag rotates the volume; the wheel spins it on the vertical axis; Shift + wheel on the horizontal axis. M26 p.131

Modifiers worth memorizing

Do thisYou getSource
Alt+click
Every viewer containing that point jumps to it (triangulation)M26 p.133
Shift+scroll or pan
Moves only that linked viewer; release to relink at the new offsetM26 p.82
Shift+Ctrl+scroll
Same correction between series of one studyM26 p.83
Ctrl+wheel over text, toolbar, or cube
Resizes overlay text, toolbar icons, or the orientation cube and scoutlinesM26 p.56, 62
Ctrlwhile drawing a line
Snaps it exactly horizontal or verticalM26 p.103
Shiftwhile drawing a contour
Adds another contour to the same ROIM26 p.120
Shiftwhile windowing a fused image
Windows the overlay instead of the base imageM26 p.41
double-click a thumbnail
Floating pop-up viewer that stays over the layout; Shift + double-click opens a second oneM26 p.74
right-drag a study date into a viewer
Adds that study as an overlay; left-drag replaces what's thereM26 p.75
holdV+drag with 3D Rotate
Rotates the image in planeM26 p.132
Ctrl+wheel on a multiframe
Steps frame by frame instead of object by objectM26 p.48

Neuro recipes

Step-by-step for the reads you do most

Each recipe is a sequence, in order. Keys use the 2026 map; swap in your build's keys if the test at the top pointed to the older map.

A

Code-stroke CTA: thick-slab MIP and obliques

For occlusions, collaterals, and a quick look at the arch-to-vertex course.

  1. Click the Thin MPR layout in the bottom toolbar. Each MPR viewer shows colored scoutlines; a line marks the plane shown in the viewer framed in the same color. M26 p.123
  2. Press T for a thick slab, then Shift+T until the viewer bar reads MIP. M26 p.125
  3. Set thickness: click a small triangle on a scoutline and drag the dotted handles, or type a value into the thickness box in the viewer bar. M26 p.69, 124
  4. PgUp and PgDn move exactly one slab at a time. M18 p.65
  5. Drag the crosshair center onto the ICA terminus or M1. Drag a rotation dot to swing the plane along the vessel for an oblique MIP. M26 p.124
  6. F9 resets the obliques to true axial, sagittal, and coronal; F10 recenters the crosshair. M26 p.132-133, 269
  7. Alt+click the cutoff to bring the noncontrast CT, and any perfusion series you loaded, to the same point. M26 p.133
  8. Save a CTA window once. Hover the lumen with the Pixel Value tool to read its HU (shown lower left), set roughly W = 2.07 × lumen HU and L = 0.72 × lumen HU, then viewer bar W/L ▾ > Window/Level Presets > Copy values from active viewer and give it a number. M26 p.118, 273-274 Saba 2009
TipAny 2D stack becomes an MPR viewer when you press a standard view key (Alt+A, P, L, R, H, F on the 2026 map), so you can reformat without changing layouts. M26 p.132
Sagittal head CTA in a Visage MPR viewer with blue and green scoutlines and the viewer bar reading C:60 W:360, Thin MPR, 1.0 mm, 36%
Sagittal CTA in an MPR viewer. The blue and green lines are the axial and coronal planes shown in the other viewers. Demo data. Source: Visage 7 Online Help v31.00, p.123, © Visage Imaging.
Move cursor at crosshair center
Center: move two planes
Two-way arrow on a scoutline
Line: move one plane
Rotation cursor on a scoutline dot
Dot: rotate (oblique)
Slab thickness handles on a dotted scoutline
Triangles: slab thickness

Cursor shapes on the crosshair. Source: Online Help v31.00, p.124.

C:60 W:360 ▾aThin MPR ▾b1.0 mm ▾c36% ▾de▾f
a
Window center and width. Click to type values, or pick a preset from the arrow.
b
Projection: Thin MPR, MIP, MinIP, AvIP. Also Viewer Type and Inverse.
c
Slab thickness.
d
Zoom; 100% is one image pixel per screen pixel.
e
Lock: detach this viewer from its linking groups; click again to rejoin. M26 p.88
f
Viewer context menu. M26 p.68-69
B

MRI: one lesion across every sequence

Stroke, demyelination, tumor: find it on one sequence, see it on all of them.

  1. Pick 4 Series or 8 Series so DWI, ADC, FLAIR, SWI, and T1 post sit side by side.
  2. Press L. Stacks with the same orientation now scroll together. M26 p.81
  3. Alt+click the lesion on DWI. Every viewer that contains that point jumps to it, including other planes and unlinked series. M26 p.133
  4. For SWI or GRE acquired as a 3D volume (cube icon on its thumbnail), press T, then Shift+T to MinIP for veins and microbleeds. M26 p.125
  5. MR signal isn't calibrated, so fixed presets travel poorly. Use Auto Window Level in ROI: draw an ellipse over the tissue you care about, and that viewer plus linked viewers re-window to it. M26 p.41
  6. Press Space before comparing subtle signal so overlay text isn't sitting on cortex.
TipPunctate DWI lesions are exactly what fast scrolling skips. Use the arrow keys, or turn on Browse Continuously from the tool palette. M26 p.45-46
Viewer bar menu open under an MPR viewer showing Viewer Type, Thin MPR, Maximum Intensity (MIP) checked, Minimum Intensity (MinIP), Average Intensity (AvIP), Inverse with shortcut I
The projection menu on any MPR viewer. Same choices Shift+T cycles through; note Inverse listed with key I on the current build. Demo data. Source: Online Help v31.00, p.125, © Visage Imaging.
C

Current vs prior: tumor, MS, hemorrhage evolution

Get the prior up, lined up, and scrolling with the current study.

  1. Open the Study Navigator (red folders, toolbar #2). Pin the priors you want and click Load. If an older study isn't listed, use Load additional studies from Archive at the bottom. M26 p.76-78 UCSD
  2. Pick a Compare layout from the bottom toolbar.
  3. Press Shift+L. Current and prior stacks with the same orientation link by the centers of their volumes. UCSD M26 p.81
  4. Off by a few slices? Scroll one side to a landmark, hold Shift, scroll the other side to match, release. M26 p.82
  5. Head tilted differently? Click Automatic Viewer Registration (chain with a red A, toolbar #21), which registers on image content including rotation. Or Alt+click the same landmark in both and click Link Current Position (#20). Check the alignment either way. M26 p.82, 89
  6. Save Registration stores the alignment as a REG series, so it's there next time. M26 p.90
  7. More than one prior loaded? Browse in All Priors (tool palette), then scroll over any prior: every prior scrolls in sync. M26 p.47
Local noteYale neuroradiology built its PACS-based brain tumor segmentation workflow on a quad MPR comparison layout with Automatic Viewer Registration. Aboian 2022
Study Navigator dialog listing a demo patient's studies by date with modality, accession number, and load checkboxes
Study Navigator. Loaded studies have a green box at right; system-suggested priors show normally; the rest are grayed. The pin keeps a prior in view. Demo data. Source: Online Help v31.00, p.76, © Visage Imaging.
D

ICH volume and midline shift

Both run off one tool: Perpendicular Distance (toolbar #15).

ABC/2

  1. Find the axial slice with the largest hematoma area.
  2. Perpendicular Distance: draw A along the longest diameter, then B across it. The tool holds B at 90 degrees and shows a right-angle mark when they meet. M26 p.107
  3. C = number of slices with blood × slice thickness. Count a slice as 1 if its hematoma area is at least 75% of the largest, 0.5 if 25-75%, and 0 if under 25%. Kothari 1996
  4. Volume in mL:

A × B × C / 2  (all in cm)

Planimetric volume

Freehand 3D ROI: trace the clot on a few slices; Visage interpolates the slices between (dashed contours) and reports the volume in cm³. New Balloon Contour grows a region by brightness, and holding Shift adds a second contour to the same ROI. Relative error is about ±3 pixels divided by the shorter radius, so zoom in. M26 p.119-121

Midline shift

On the slice through the septum pellucidum, draw the first Perpendicular Distance line from the anterior to the posterior falx attachment. Draw the second from the septum pellucidum to that line. The second length is the shift.

Tools you'll use

Perpendicular Distance (toolbar #15)
Freehand 3D ROI (measurement tools)
New Balloon Contour (inside Freehand ROI)
Partial crosshair, X: hides the crosshair center so you can start a line near it M26 p.61
Measure rightDistance accuracy is ±2 pixels, and worse when the image is zoomed out. Zoom into the structure before you draw. M26 p.102
E

Images for morning report, de-identified

From viewer to slide without carrying identifiers along.

  1. File > Privacy Mode > View Screen Only hides identifying information until you set it back to Off. M26 p.249
  2. Space hides overlay text. Toggle Patient/Study Data hides only demographics and keeps your arrows and measurements. UCSD
  3. Press S (or Shift+S for all viewers). The image lands in the Export tab: right-click, Copy, paste into PowerPoint. To skip that step, turn on File > Preferences > Properties > General Configuration > Copy Screenshot to Clipboard. UCSD
  4. For images with burned-in text (ultrasound, scanned forms), use Export Image or Clip with Mask Patient Header. It can also send one image straight to the clipboard or a file, or save a cine clip. It isn't available for obliques or 3D. M26 p.249
  5. Look at every exported image for burned-in identifiers before it leaves the workstation, and follow YNHH policy.
Save the caseFile > Save Session keeps the layout, key views, screenshots, and measurements. You choose private or shared, and you reopen it from the session list in the Study Browser. Sessions are not archived with the study. M26 p.205-207
Send a caseFile > Copy Study Link copies a link that opens the study in a colleague's Visage. Send it only through an approved secure channel. M26 p.208
Collect casesRight-click a study in the Study Browser > Study Labels, type a name, and tick the private version. Later, Search Conferences and Labels > click the label to list every case you tagged. M26 p.237-238, 243
CarefulSave Result writes a presentation state (a PR series) that loads for anyone who opens the study. Study comments also save to the server; tick private if one is just for you. For personal notes on a case, save a private session. M26 p.204, 241

Thumbnails & priors

What you've loaded, and what you've actually seen

The thumbnail strip along the bottom tracks every series. G hides or shows it on the 2026 map.

Thumbnail labeled 9: TOF_3D_multi-slab, 104 images, cube icon
CubeA volume. MPR, MIP, and T work on it.
Thumbnail labeled 7: ep2d_diff_3scan, 2x23 images, cube and folder icons
Cube + folderSeveral volumes in one thumbnail, like DWI b-values (2×23).
Thumbnail labeled Localizers, 6 images, folder icon
FolderSeparate images, like localizers. Not a volume.
Thumbnail labeled 1: t2_blade_tra, 31 images, green border and solid green corner triangle
Green border + triangleIn the active viewer; a solid triangle means every image was viewed.
Thumbnail labeled 301: SAG T1, 15 images, gray corner triangle
Gray triangleWas on screen earlier in this session, not now.

Thumbnails from the UCSD Radiology Visage 7 Viewer FAQ. UCSD

Read the badges

  • Hollow triangle: on screen, not every image viewed yet. Solid: all viewed. A volume counts as viewed without scrolling every slice. UCSD
  • Yellow star: the series has a key view. Yellow plus: new images arrived since you opened the study. Hatched background: a prior that isn't loaded yet. M26 p.70-71
  • Study date borders: white is the current study, red a prior, green a newer study. M26 p.71
  • Show Unseen Images Warning (tool palette, or put it on a key) lists what you haven't looked at, localizers included. A preference can also warn you on close. UCSD

Moves in the strip

  • Drag a thumbnail into a viewer to load it; drag a study date to load the whole study. M26 p.74-75
  • Double-click a thumbnail for a floating pop-up viewer, handy for a scout. M26 p.74
  • Right-click the strip for Show DICOM Series (one thumbnail per series), Sort by time, or Show Reports. M26 p.71-72
  • The slider at the left end of the strip reveals more priors; the pin keeps one in view. M26 p.73
  • New images arrived mid-read? The Study Navigator icon gets a plus, and Update Session loads them while keeping your measurements. M26 p.79
  • Lost a patient you opened earlier? The Recent Studies tab in the Study Browser. UCSD

Window presets

Put your neuro windows on 1 to 9

Presets are stored per modality and follow your login to any workstation. The key numbers are a suggestion; the values come from the cited sources.

KeyPresetWidthLevelSource
1Brain8040Radiopaedia
2Subdural130-30050-100Radiopaedia
3Stroke8 or 4032 or 40Radiopaedia
4Temporal bone2800600Radiopaedia
5Spine bone1800400Radiopaedia
6Neck soft tissue350-40020-60Radiopaedia
7CTA review and calcified plaque
Scale to lumen HU. Lumen 350 HU gives W 725, L 252.
2.07 × lumen0.72 × lumenSaba 2009
8CTA stenosis calipers
Phantom study, lumen 250-350 HU. Narrow on purpose.
96150Liu 2000
0Default windowset by protocol or DICOMM26 p.273
Shift+12
Windows stored in the DICOMfrom the scannerM26 p.273

Where a source gives a range, save one value inside it. Read lumen HU by hovering the Pixel Value tool over the vessel; the value shows in the lower left of the viewer. M26 p.118

Window level menu from the viewer bar: Default 0, DICOM 1 Shift+1, DICOM 2 Shift+2, MyPreset 1, Window/Level Presets
The W/L menu in the viewer bar lists each preset with its key. Source: Online Help v31.00, p.273, © Visage Imaging.
MRSignal isn't calibrated. Use Auto Window Level in ROI, or save a preset set to Automatic W/L based on histogram. Put Next Window Level on a key or thumb button to cycle presets. M26 p.41-42, 274

Save a preset

  1. File > Preferences > Window/Level Presets, or the W/L arrow in the viewer bar > Window/Level Presets. M26 p.273
  2. Pick the modality and a preset number. 1 to 9 get keys; 10 and up are menu-only.
  3. Name it and enter Center and Width, or click Copy values from active viewer.
  4. Click Save Preset. It follows you to every workstation. UCSD

Key map

Every documented key, filterable

From the keyboard dialog screenshots in the 2018 and 2026 manuals, plus keys described in the manual text. YNHH may have remapped some; your Help > Keyboard Shortcuts list wins.

KeyDoesMapSource
wheelโ†‘โ†“
Previous or next sliceBoth mapsM26 p.45
HomeEnd
First or last sliceBoth mapsM18 p.65
PgUpPgDn
Previous or next thick slabBoth mapsM18 p.65
Ctrl+โ†โ†’
Previous or next volumeManual textM18 p.67
โ†โ†’
Previous or next phase of a time seriesManual textM18 p.67
Ctrl+โ†‘โ†“
Next or previous frame of a multiframeManual textM18 p.66
F6
Browse Slices toolBoth mapsM26 p.269
.,
Next or previous viewer2026 mapM26 p.269
><
Next or previous viewer2016-18 mapM18 p.192
+-
Next or previous study from the Study Browser list2026 mapM26 p.55, 269
NShift+N
Next or previous N series2026 mapM26 p.54, 269
F8Shift+F8
Next or previous image set2026 mapM26 p.54, 269
G
Show or hide the thumbnail strip2026 mapM26 p.71, 269
double-click viewer
Solo that viewer; again to returnManual textM26 p.65
01to9
Default window; your presets 1 to 9Manual textM26 p.273
Shift+12
Windows stored in the DICOMManual textM26 p.273
F1
Default Navigation toolBoth mapsM26 p.269
F3F4F5
Pan, Zoom, Window Level toolsBoth mapsM26 p.269
I
Invert2026 mapM26 p.125, 269
.
Invert2016-18 mapM18 p.56
F
Fit image to viewer2026 mapM26 p.269
R
Rotate in plane2026 mapM26 p.269
Space
Hide or show overlay textManual textM18 p.117 UCSD
O
DICOM overlays on or offBoth mapsM26 p.62, 269
X
Partial crosshair: hides the center so you can measure near itBoth mapsM26 p.61, 269
T
Thin slices or thick slabBoth mapsM26 p.125
Shift+T
Cycle MIP, MinIP, AvIPBoth mapsM26 p.126 M18 p.50
F2
3D Rotate toolBoth mapsM26 p.269
F7
Triangulation tool2026 mapM26 p.133, 269
F7
Position Crosshair tool2016-18 mapM18 p.192
Alt+click
Triangulate: every viewer jumps to that pointManual textM26 p.133
F9
Reset slice orientations (undo obliques)Both mapsM26 p.132, 269
F10
Center the view on the crosshairBoth mapsM26 p.133, 269
Alt+APLRHF
Anterior, posterior, left, right, head, foot view; turns a 2D viewer into MPR2026 mapM26 p.132, 269
APLRHF
The same six standard views2016-18 mapM18 p.102
E
Switch the active vessel slider (vessel analysis)Both mapsM26 p.269
J
All linking on or offBoth mapsM26 p.81, 269
L
Automatically link viewers in this study2026 mapM26 p.81, 269 UCSD
Shift+L
Automatically link current and priors (frames of reference)2026 mapM26 p.81, 269
I
Link Current Position2016-18 mapM18 p.192
Shift+scroll
Re-sync one linked viewer, then releaseManual textM26 p.82
A
Arrow and text annotation2026 mapM26 p.269
N
Arrow and text annotation2016-18 mapM18 p.83
D
DistanceBoth mapsM18 p.85 M26 p.269
Ctrl+CCtrl+V
Copy or paste an annotation or ROIManual textM26 p.92, 114
S
Screenshot of the active viewerBoth mapsM18 p.99 M26 p.269
Shift+S
Screenshots of all viewersBoth mapsM18 p.100
Alt+S
One combined screenshot of all viewersBoth mapsM18 p.100
K
Store key viewBoth mapsM18 p.100 M26 p.269
F11F12
Previous or next key viewBoth mapsM26 p.269
C
Cine play or pauseBoth mapsM26 p.269
V
Reports from PACS2026 mapM26 p.213, 269
Ctrl+P
Print, or save images as a PDFManual textM26 p.210
Ctrl+K
Keyboard shortcut editorManual textUCSD
Ctrl+N
New session: clears your changes and reapplies the protocolManual textUCSD M26 p.207
Ctrl+wheel
Resize overlay text, toolbar icons, thumbnailsManual textM26 p.56, 62
Help > Keyboard Shortcuts, thenCtrl+ACtrl+C
Copy your build's full key listManual textM18 p.54
Both maps same key in 2018 and 20262026 map 2026 manual2016-18 map older manualsManual text described in text, not in the dialog
Configure Keyboard Shortcuts dialog from the 2026 manual showing tools assigned to function keys, letters with Shift and Alt rows, and special keys
File > Preferences > Keyboard Shortcuts (Ctrl+K). Drag a tool from the list onto a key box; the Shift+ and Alt+ rows hold combinations. Source: Online Help v31.00, p.269, © Visage Imaging.

Make it yours

Ten minutes of setup that pays back all year

Keys, presets, and the right-click palette are saved to your login and follow you to any workstation. Monitor configuration is saved per workstation. UCSD

Keys

Ctrl+K, or File > Preferences > Keyboard Shortcuts. Search for a tool and drag it onto a key; Shift and Alt combinations work. Revert to System Defaults undoes everything. M26 p.268-270 UCSD

Free on the 2026 map: H, M, P, Q, U, W, Y, Z, and most Shift and Alt slots. Suggestions for neuro:

HToggle Annotations. UW Medicine hands this one out as a job aid. UW WAuto Window Level in ROI, for MR MNext Window Level, to cycle presets PStudy Navigator, for priors QLink Scrolling YAutomatic Viewer Registration UShow Unseen Images Warning ZMagnifying Glass

Mouse buttons and right-click palette

File > Preferences > Mouse Buttons puts tools on extra buttons; a gaming mouse works. M26 p.272 UCSD

File > Preferences > Tool Palette sets the grid you get on right-click, and whether right-click shows the palette, the context menu, or both. M26 p.270-271

Good palette picks for neuro: Triangulation, Browse in All Priors, Browse Continuously, Auto Window Level in ROI, Freehand 3D ROI, Show Unseen Images Warning.

Triangulation Browse in All Priors Browse Continuously Auto Window Level in ROI Freehand 3D ROI Next Window Level

Layouts and toolbars

Right-click a layout button > Add to Default Layouts or Make Layout the only Default. Then right-click > Save Layout Preferences, or the change is lost. Saved per protocol. M26 p.68 UCSD

New Layout and Clone Layout are on the same right-click menu; the pencil (Modify Layout) re-grids a monitor on the fly. M26 p.65-67

Right-click empty toolbar space to show or hide toolbars, then View > Show Toolbars > Save Toolbar Settings. M26 p.56

Display comfort

View > UI Appearance: Visage Dark, Medium, or Bright, to match the room. M26 p.266

Ctrl + wheel over text or toolbars resizes them; the size is kept for monitors of about the same size. UCSD

Wide multi-monitor desk: File > Preferences > Properties > User Interface > Show Mini Drop Zone, so you don't drag thumbnails across three screens. M26 p.74

Dismissed a warning for good and want it back? View > Reset All Warnings. M26 p.275

Read safely

When the screen isn't showing you everything

Red bullet, lower right

Reduced resolution: the study is still streaming or a low compression level is set. Don't read from it. M26 p.58

Yellow bullet

Your last processing step hasn't rendered yet, and the previous image is still showing. M26 p.58

Yellow triangle, upper left

The dataset has warnings. Click the triangle to read them. M26 p.58

Fast scrolling skips slices

Mouse Wheel Acceleration is on by default. Use the arrow keys or Browse Continuously for small lesions. M26 p.45-46

Registration can be off

Automatic linking and registration can misalign current and prior. Check a landmark before calling a lesion unchanged. M26 p.82

Measure zoomed in

Distances are ±2 pixels and ROIs ±2 to 3 pixels over the shorter radius, with larger errors when zoomed out. M26 p.102, 113, 119

The manual's own rule: do not use images showing a red or yellow bullet for primary diagnosis. M26 p.58

Sources

Where each claim comes from

Page numbers are the printed pages of each manual. Manual screenshots use Visage's demo data.

  1. M26Visage Imaging. Visage 7 Online Help, document version 31.00, September 2026. hirc.cloud.visageimaging.com/Lang_Dep/Visage7_Client_OnlineHelp_EN.pdf
  2. M18Visage Imaging. Visage 7 Client Online Help, document version 16.00, 2018. Tool names carry their factory keys in brackets. visageimaging.com/downloads/Visage7/archive/Visage7_Client_OnlineHelp_EN_V16.pdf
  3. M16Visage Imaging. Visage 7 Client Online Help, document version 13.00, 2016. Same older key assignments as M18. visageimaging.com/downloads/Visage7/archive/Visage7_Client_OnlineHelp_EN_V13.pdf
  4. UCSDUC San Diego Radiology. Visage 7 Viewer FAQ, 2022. radres.ucsd.edu/documents/Visage7_Viewer.pdf
  5. UWUW Medicine PACS Help. Visage 7 Training (includes the job aid for toggling annotations with H). depts.washington.edu/pacshelp/docs/Training/visage.html
  6. PR 2017Visage Imaging. Visage Signs Yale New Haven Health. Press release, 20 November 2017. visageimaging.com/press-release/visage-signs-yale-new-haven-health
  7. AboianAboian M, Bousabarah K, et al. Clinical implementation of artificial intelligence in neuroradiology with development of a novel workflow-efficient picture archiving and communication system-based automated brain tumor segmentation and radiomic feature extraction. Front Neurosci. 2022. CC BY. doi.org/10.3389/fnins.2022.860208
  8. RPBell DJ, Murphy A, et al. Windowing (CT). Radiopaedia.org. radiopaedia.org/articles/windowing-ct
  9. SabaSaba L, Mallarini G. Window settings for the study of calcified carotid plaques with multidetector CT angiography. AJNR Am J Neuroradiol. 2009;30(7):1445-1450. ajnr.org/content/30/7/1445
  10. LiuLiu Y, Hopper KD, Mauger DT, Addis KA. CT angiographic measurement of the carotid artery: optimizing visualization by manipulating window and level settings and contrast material attenuation. Radiology. 2000;217(2):494-500. doi.org/10.1148/radiology.217.2.r00oc32494
  11. KothariKothari RU, Brott T, Broderick JP, et al. The ABCs of measuring intracerebral hemorrhage volumes. Stroke. 1996;27(8):1304-1305. doi.org/10.1161/01.str.27.8.1304
  12. Ease ProVisage Imaging. Getting Started: Visage Ease Pro, version 19.00, May 2023. visageimaging.com/downloads/VisageEase(Pro)/VisageEasePro_GettingStarted_EN-US.pdf